  • XenServer: How to Build and Configure a Dedicated NFS Storage Bond

    GodzukiFirst of all let me start this off by saying that there is a lot of information out there on how to setup a dedicated storage interface on XenServer. However, I was unable to find anything specifically related to bonding two unmanaged interfaces and use them for as a dedicated uplink, which is seems rather silly to me as why would you not want to have a highly redundant network connection to your NFS storage. I digress.

    Anyway, the first thing you need to do is to ssh into one of your XenServer hosts. In my environment I am building out a three node cluster and I need to make sure that I am working specifically with the first host in the cluster. So….

    First thing you need to do is change the network backend of your Xenserver from "openvswitch" to "Linux Bridge". You accompish this with the following command.

    #xe-switch-network-backend bridge.

    Now you will need to reboot. Note that you can check your network-backend mode at any time with the following command.

    #cat /etc/xensource/network.conf

    First get the uuid of the local xenserver host, use the hostname to do this.

      # xe host-list name-label=xen01

    The command above will return the uuid of the server.

    uuid ( RO): 4a9971f7-1e59-4e02-b849-04d206ee7b2b
    name-label ( RW): xen01
    name-description ( RW): Default install of XenServer

    Then you need to get a list of pifs on the host that you are working with (making sure to exclude any other host's interfaces). The command below will output this list. We will need to grab the uuids of eth2 and eth3, since they are the interfaces that we are going to use to build our bond. Note that we are running this command so that it will spit out our MAC addresses as well… make sure that you take note of these as you will need them.

     #xe pif-list host-uuid=4a9971f7-1e59-4e02-b849-04d206ee7b2bparams=uuid,device,MAC,host-uuid

    Next we will tell XenServer to "forget" or un-manage eth2. Then we will do the same to eth3. We will use the uuids of these interfaces to identify them to XenServer.

    Example with interface eth2 in unmanaged mode. Rinse and repeat for eth3.

    # xe pif-forget uuid=97afe085-c679-3aa0-d09b-3c530ee3ac60

    Then list all PIFs to ensure the unmanaged one is no longer in the list:

    # xe pif-list host-uuid=97afe085-c679-3aa0-d09b-3c530ee3ac60

    If you have successfully removed them its time to start creating your bond.

    First define your bond in /etc/modprobe.conf. I am calling my bond, bond51

    alias bonding bond51
    options bond51 miimon=100 mode=7
    

    Then edit /etc/sysconfig/network-scripts/ifcfg-eth2 and /etc/sysconfig/network-scripts/ifcfg-eth3. Make them look like the file below. Change the device name for ifcfg-eth3 to eth3.

    DEVICE=eth2
    BOOTPROTO=none
    HWADDR=<MAC ADDRESS OF YOUR INTERFACE>
    ONBOOT=yes
    MASTER=bond51
    SLAVE=yes
    

    Then create /etc/sysconfig/network-scripts/ifcfg-bond0

    DEVICE=bond51
    IPADDR=<YOUR IP>
    NETMASK=<YOUR NETMASK>
    ONBOOT=yes
    BOOTPROTO=static
    

    Beep Boop. Ifup bond51 to bring up the bond and its slave members.

    You can check the status of the bond via the command below.

    cat /proc/net/bonding/bond51

    Please know that I have done little more than reboot the XenServer host to make sure that the configuration that I built would persist across reboots, and failover from one interface to another. I have not tested performance yet in any way shape or form.

  • How to Check Mulitpathing in Veritias Volume Manager

    Multipass-01Today while working in the Datacenter,  I accidentally destroyed a fibre cable running to one of our database servers. All the databases went poof and the DBAs freaked out. After I reminded them that this was a non-production database I went about running a new fibre cable.

    Being that this box was dual pathed back to the SAN, the server should have had additional paths back to its disks and the databases should have keep running along just fine. However,  as luck would have it, the secondary path was down at the time I destroyed the primary.

    Anyway after reseating the secondary fibre and running a new primary cable I was able to verify that I had multiple connections back to the disks with the following commands.

    # vxdmpadm getdmpnode dmpnodename=3pardata0_4641
    
    NAME                 STATE        ENCLR-TYPE   PATHS  ENBL  DSBL  ENCLR-NAME  
    ==============================================================================
    3pardata0_4641       ENABLED      3PARDATA     4      4     0     3pardata0

    Where 3pardata0_4641 is the disk name and PATHS is obviously the number of paths back to the SAN disk.

    Even better yet you can check DMP (dynamic multipath status) for all disks with the command below.

    # vxdmpadm getdmpnode

  • Broadcom (bnx2) Network Adapters Dropping Recieved Packets Under Linux

    VampSo a few weeks ago some of our Centos 5.4 and OEL 5.5 servers started exibiting strange connectivity problems. Monitoring started alerting that hosts were down when they weren't; some boxes could ping target hosts and some couldn't; some boxes became unresponsive when interfaces were failed over, and the strangest of all is that some of the boxes would magically "repair" themselves. Like I said, strange.

    Over the next week or so we ran into the issue a few more times and were able to see a pattern emerge. All the affected servers were running Centos 5.4 or Oracle Linux 5.5 and had broadcom (bnx2) adapters that were on the recieving end of some pretty decent traffic. Most importantly, all had a good number of dropped recieved packets that was continuously, albeit slowly, increasing.

    A bit of google research led us to this bugzilla, which suggested changing the adapter's coalescense settings…. so a bit on coalescense.

    Coalescense

    In your network adapter, coalescence is all about interupts. Traditionally interupt coalescense (or IC) is used to reduce the number of interupts generated by the system by delaying the generating of an interrupt by a very short period of time…think less then a milisecond. In turn more traffic will be recieved by the host and the next interupt generated will be larger in size. You can find out more than you would ever want to know about coalesence here

    The Fix

    So apparently the Broadcom IC settings were not aggressive enough. Packets would come in, fill up the receive queue, and get dropped before they could be sent off for processing via an interrupt. This takes us back to the bugzilla above and the suggested settings below which you set with the ethtool command

     ethtool -C ethX rx-usecs 8 rx-usecs-irq 8 rx-frames 0 rx-frames-irq 0

    Note that this was not an issue on any in Centos 5.6, any server with Intel adapters, or any server with 10g adapters. As a matter of fact, those servers had IC settings even more agressive then those above. See the Intel 82599EB 10-gigabit settings below

    rx-usecs: 1
    rx-frames: 0
    rx-usecs-irq: 0
    rx-frames-irq: 0

    Final Configuration

    So now that we know the fix we need to make it permanent, which is not as easy as editing a config file for the device as the coalescence config is set at boot and it part of the installed driver for the device. Rather than muck around with trying to modify the driver itself, we decided to set and configure our devices at boottime with a rc script that checks the checks the each network interface on the box and modifys their IC settings if they are using the bnx2 (Broadcom) driver.  We dropped the script below into /etc/rc.d and created a symbolic link to it in /etc/rc3.d.

    #!/bin/bash

    case "$1" in
    start)

    IFACE=$(ls /etc/sysconfig/network-scripts/ifcfg-eth*| grep -v bak | cut -d – -f 3)

    for ETH in $IFACE
            do
                    if ( ethtool -i $ETH | grep -qw bnx2 )
                    then
                            echo "$Changing Settings for $ETH"
                            ethtool -C $ETH rx-usecs 8 rx-usecs-irq 8 rx-frames 0 rx-frames-irq 0
                    else
                            echo "$ETH is not a broadcom"

                    fi
            done
    exit 1
    ;;

    stop)

    echo " hammer time"
    ;;

    *)
        echo "usage: $0 (start|stop)"
    ;;
    esac

  • Very High snmpd CPU Usage and 1000s of IP Addresses

    Clipper_fistFor a while now we have been experiencing SNMP timeouts from our central monitoring server to a set of new and recently deployed servers. We at first attributed the issue to the network driver being a bit different than what we have used in the past (latest greatest hardware) and then to the fact that we are completely gutting our production network in situ. Normalization of the driver across this application farm made no difference and the issue began to get worse, spreading to just about all servers in this one specific service tier. As it was not impacting any other servers it wasn’t surprising that we could not find an issue at the network layer so we had to keep digging.

    In our environment this tier is unique for two reasons:

    1. Very high IO per server. On the order of 10,000 write ops to disk per second at peak load.
    2. Thousands of private IPs per system (added as ip rules – not virtual addresses on interface devices).

    The first issue was in fact an issue, just not for SNMP.

    The snmpd process was getting lost in the noise generated by the high system load the disk IO was causing (lots or concurrent processes in this app). The team quickly addressed this issue and scaled the IO subsystem substantially to meet the growing workload. After this change the system load dropped from over 1000 to under 10 (1 minute average) during peak utilization on these servers.

    Unfortunately snmpd was still timing out. However, now with the noise of all those blocked processes out of the way, running a top showed the snmpd process stuck at 100 percent cpu usage for very long period of times. In fact, periods of less than 100 percent cpu were noted for their rarity.

    That led us to difference number two. Recently we had been normalizing our system configurations which resulted in the whole tier of afflicted servers having even more IPs assigned. Ok great the team thought – we know where that lives in net-snmp – the IP-MIB. Our assumption was that net-snmp should only refresh this MIB based on client requests and for some reason our monitoring solution was requesting all the IPs from the IP-MIB portion. That would certainly explain the timeouts we thought. Step one was try the latest net-snmp just in case it was bug on our old default 5.4 install. No change. So the team’s next step to trouble shooting this was to essentially block access to the ip-mibIP-MIB part of the OID tree.

    We tried various versions of:

    view systemview excluded ip.ipAddressIfIndex.ipv4

    view systemview excluded ip.ipAddressType.ipv4

    view systemview excluded .1.3.6.1.2.1.4.20.1

    and so on to no effect. Next we did the obvious test – block all client access. No change – snmpd was still consuming 100% of a cpu all the time. Now what?

    Unfortunately we were not on Solaris so no DTrace. However, strace did provide the clues needed to make progress. The strace of the snmpd process was almost entirely ioctl calls to the interface devices to fetch the IP addresses associated with them. These calls themselves were not so much the issue as the response time of the ioctl calls were in microseconds. A continuous snmpget was executed against a system while the strace was generated and the strace output compared to client experience. Client time outs lined up exactly with when the ioctl “storm” would start. As the system time consumed was tiny by snmpd during this, the issue had to be in the user-land component of net-snmp.

    One thing the strace showed was snmpd was almost alway determining all the IPs on each interface in what looked like a very tight loop. There was perhaps two to three seconds between each storm. In addition, each subsequent ioctl call involved more and more IPs per call – almost displaying an O(n^2) behavior as the list of IPs in the previous call were then being listed again with only the addition of another IP. So now we knew snmpd was, for some reason, always rebuilding the .1.3.6.1.2.1.4 tree and doing it a nasty way.

    The first thing that jumped to mind was somewhere the caching we assumed Net-SNMP would do on the ip table was misconfigured. We attacked the nsCacheTable and its ilk from all directions. No luck and no change in behavior. At this point a more thorough web search found two similar postings describing high snmpd cpu usage. One for system with a very large BGP routing table and another for a system with thousands of VLANs. Neither indicated a solution though the BGP postings indicated that sorting within snmpd was not very efficient. At this point your author started to change some of the cache constants within the net-snmp source code to see if the polling cycle on the interfaces would change. It did not.

    Time to turn on debug :
    The snmpd daemon that comes with Net-SNMP has a pretty thorough debug mode. So thorough in fact we went to that step last as in our environment the full debug mode generates about 75MB of log data every five seconds (remember all those ip addresses). We had tried various documented methods to only have it run debug on certain sub-modules like the IP-MIB, but we could not find an actual working command line option. The documented examples on the net-snmp wiki pages did not work at all on our build for some reason. So we were forced to deal with the fire hose of logging everything.

    With full debug on (-DALL) snmpd was started. Five seconds or so was all that was needed to generate a trace that would help us track down the issue. The net-snmpd agent code is full of logging code like below:

    DEBUGMSGTL(("access:ipaddress:container", "processing %d interfaces\n", interfaces));

    which will generate a message like:

    trace: _netsnmp_ioctl_ipaddress_container_load_v4(): ip-mib/data_access/ipaddress_ioctl.c, 171:
    access:ipaddress:container: processing 4 interfaces

    This makes it very easy to find where in the code the message was generated and simplifies tracing the application (relatively – there are 100s of modules). So at this point we did the tedious task of simply walking the log file in parallel with walking the code, focusing obviously on the interface and IP portions. Along the way numerous little hooks and debug messages were dropped into the code and snmpd recompiled. This helped us along the way to at least realizing the real problem was much larger than what we wanted to tackle. Essentially, the table access and cache components just will not work when one has 1000s of IP addresses. Best we could tell, snmpd is resorting the IP oid tree after each and every IP address it comes across. If you follow the snippets of debug out put below you will see how it does a table compare after each and every IP on a small test system. On our production box with over 7000 IPs snmpd is spending all its time doing index compares. The full debug snippet is available if anyone wants it.

    Realizing there was no way for us to quickly and safely modify either the cache code which honestly, we couldn’t figure out why the IP table was called as often as it was. Even interface stats (.1.2.1.3.6.1.2.1.2.2) were being refreshed at a much higher refresh rate than nsCacheTable would imply] or the table and index code we decided to cut the monster off at the head – the call into the “access:ipaddress:container” portion of the code. Through a bit of debugging your author determined the head of the monster was the _netsnmp_ioctl_ipaddress_container_load_v4 function in the ip-mib/ipAddressTable/ipAddressTable_interface.c source file. This function seemed to lead to the discovery of all the IP addresses associated with an interface and hence all the sorting, indexing, and other madness we were experiencing.

    Solution
    The solution is neither pretty nor elegant and is a bit of the nuclear fly-swatter type. The function identified above loops over all the physical interfaces with IP addresses assigned. In our case that is the loopback and a set of bonded interfaces on various VLANs. Lucky for us, the 1000s of IPs we have on each server are on a set of dedicated bonds on their own VLANs. These are completely separate from the base server VLAN and other “user experienced” addresses. In addition, there is nothing related to these addresses in SNMP that we have ever used or need to use via snmp. As we determined, our monitoring software didn’t even know these IPs existed nor really ever hit anything in the IP-MIB table. All it ever knew or cared about was the base IP assigned to each bonded interface.

    So in our case, the obvious solution was to just not even process these bonded interfaces to determine what IP addresses were on them. We found some references in the code to essentially leverage ablack list but we could not figure out how to use it. As such we did the next best thing – modified the code of the loop in the _netsnmp_ioctl_ipaddress_container_load_v4 to just skip a set of known bonds – essentially do something like:

    [code language=”css”]

    if (strcmp(ifrp->ifr_name,”bond1.16″) == 0) { DEBUGMSGTL((“access:ipaddress:skipping”, ” interface %d, %s\n”, i, ifrp->ifr_name)); continue; }
    [/code]

    The full diff is below. Note the code was written so it would be easy to generate a patch based on our automation tools (i.e. if new bonds come and go) and to be obvious to folks without much C experience to know what to change. Not super efficient but good enough. After making this change snmpd CPU usage went from a continuous 100 percent to under 0.5 percent. Better yet – no more timeouts! All we lost was access to the portion go the IP table for the excluded interfaces. Something we didn’t use anyways.

    We still don’t know why snmpd was determined to rebuild the ip-mib continuously. As our use case is probably pretty rare it is not surprising there are so few reports of this behavior.

    [code language=”css”]

    — ipaddress_ioctl.c.new +++ ipaddress_ioctl.c.orig @@ -165,11 +165,6 @@ DEBUGMSGTL((“access:ipaddress:container”, ” interface %d, %s\n”, i, ifrp->ifr_name)); – /* Ops was here */ – – DEBUGMSGTL((“access:ipaddress:containerSPNew”, – ” interface %d, %s\n”, i, ifrp->ifr_name)); – if (AF_INET != ifrp->ifr_addr.sa_family) { DEBUGMSGTL((“access:ipaddress:container”, ” skipping %s; non AF_INET family %d\n”, @@ -177,36 +172,6 @@ continue; } – /* Working around issue with 6000 IPs on a host – * So we exclude known problem interfaces – */ – – if (strcmp(ifrp->ifr_name,”bond1.16″) == 0) { – DEBUGMSGTL((“a ccess:ipaddress:skipping”, – ” interface %d, %s\n”, i, ifrp->ifr_name)); – continue; – } – – if (strcmp(ifrp->ifr_name,”bond1.20″) == 0) { – DEBUGMSGTL((“access:ipaddress:skipping”, – ” interface %d, %s\n”, i, ifrp->ifr_name)); – continue; – } – – if (strcmp(ifrp->ifr_name,”bond1.24″) == 0) { – DEBUGMSGTL((“access:ipaddress:skipping”, – ” interface %d, %s\n”, i, ifrp->ifr_name)); – continue; – } – – if (strcmp(ifrp->ifr_name,”bond1.28″) == 0) { – DEBUGMSGTL((“access:ipaddress:skipping”, – ” interface %d, %s\n”, i, ifrp->ifr_name)); – continue; – } – – /* End Ops Hack */ – /* */ entry = netsnmp_access_ipaddress_entry_create();

    [/code]

  • Poor Man’s eSATA Drive Hot Swap without AHCI or Hotplug Support Under Linux

     

     

    ServerRoomFireWeb

    Unfortunately, hot-swapping an eSATA drive is a bit more complicated than hot swapping a USB drive.

    First off,  your BIOS needs to support AHCI (click here for more info on AHCI), and your SATA controller also needs to support it as well. Secondly your OS, needs to specifically support hot plug, and in the case of Windows 7, it wont boot if you change to AHCI after the OS has been installed.

    So, In my case I need to update firmware on lots of SATA SSDs and want to do so without rebooting, and without worrying about changing bios settings. So in order to keep things simple, I followed the procedure below.

    First, you need to detect your drive. So watch dmesg to see what drive letter is assigned to your new disk upon initial connection.

    #dmesg

    [86527.985994]  sdd: unknown partition table
    [86528.012820] sd 8:0:0:0: [sdd] Assuming drive cache: write through
    [86528.012823] sd 8:0:0:0: [sdd] Attached SCSI disk
    [86528.456281] device label btrfs devid 1 transid 11 /dev/sdd

    Then, when its time to remove the disk device to the following. Subsitute your disk device letters.

    # echo 1 > /sys/block/sdd/device/delete

    Now you are free to swap your disk. No reboot, no bios changes, required.

  • Configuring Remote Syslog in ESXi 4.1 via the Linux RCLI

    Groundhog

    First thing you need to know about ESXi is that it rolls its log after a reboot, meaning if your ESXi server crashes there will be no logs to review and no way of knowing what when to hell and where.

    For this reason it is imperative that you setup a remote syslog server and send your logs there. Vmware support will tell you this and shame you if you have not setup remote syslogging.

    Fortunately the first hit on google for “ESX syslog how to” will take you directly to the VMware KB article. You can find it here. However this page does not contain directions on how to do this via the Linux rcli, it only contains directions on how to do this via the VMA (management appliance) and from Windows PowerCLI. Really Vmware?

    Follow the directions below if you run a real operating system and are not a Windows Admin.

    First configure your remote ESXi host to forward syslog to your syslog server.

    esxcfg-syslog –server esx04 –setserver vsyslog02 –setport 514

    Then verify your settings

    esxcfg-syslog –server esx04 –show

    Output will appear as follows if everything worked right.

    Current remote syslog server settings:
    Server name : (vsyslog02)
    Server port : 514

  • Patching ESXi 4.1 via the Linux RCLI

    PIRATE_MASK_IMAGE_rdax_65

    Great Balls of Frustration… could the documentation be anymore confusing and convoluted regarding the process of patching an ESX server via the Linux remote cli.

    No, I am not running windows, and no I am not on the local ESX console, and no I am not running the Vmware Management Appliance, and most of all, no I do not want outdated instructions from 2008. I just want to download some patches to my local linux destop and patch my ESX servers. Specifically I want to install the latest and greatest Qlogic drivers to troubleshoot a SAN connectivity issue that I will probably blog about at a later date.

    Anyway here is how I did what I needed to do without resorting to using a windows box.

    First download the driver isos to your local Linux desktop and mount the isos up locally,

    mount -o loop vmware-esx-drivers-scsi-fnic_400.1.4.0.201-1vmw.2.17.00000.491446.iso /mnt

    Second locate the offline-bundle directory. I moved mine off to another directory that I created specifically for the Qlogic Driver. This way I dont have to unmount and remount the iso when i patch my other boxes.

    Next put the host in maint mode.

    vicfg-hostops –username root –server esx04 -o enter

    Then navigate to the offline_bundle directory and run the following command, replace the bundle name that I used with the bundle name in your directory

    vihostupdate –server esx04 –install –bundle 841.k1.16.2-1vmw-offline_bundle-340223.zip

    Wait for the following message

    Please wait patch installation is in progress …
    The update completed successfully, but the system needs to be rebooted for the changes to be effective.

    Then reboot

    vicfg-hostops –username root –server esx04 -o reboot